Welding Fume Testing Laboratory in Houston, TX
AGT Labs analyzes samples collected by your industrial hygienist, EHS team or consultant — drop off in Houston or ship from anywhere in the U.S. ICP-AES analysis for manganese, iron oxide, nickel, hexavalent chromium, cadmium, lead, zinc oxide and 30+ metals from a single filter, with NIOSH 7300 Modified / 7303 compliance reporting for personal breathing-zone assessments and LEV validation. AIHA LAP accredited (LAP-101470) and ISO/IEC 17025:2017 — results reported against both the OSHA PEL and the ACGIH TLV, accepted nationwide.
We're the accredited lab behind your sample results
A welding fume or industrial hygiene inspector or consultant? Submit your MCE and Cr(VI) cassettes to our AIHA LAP-accredited ICP lab under your own independent-lab account — per-metal µg/m³ concentrations with OSHA PEL and ACGIH TLV comparisons formatted for your reports.
What is welding fume testing?
Welding fume testing collects airborne metal particulate from a welder's breathing zone on a calibrated pump and MCE filter, then analyzes that filter by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES). The instrument atomizes and ionizes the acid-digested filter in a ~8,000°C plasma and quantifies each element by its emission spectrum — simultaneous quantification of 30+ metals from one filter, each reported in µg/m³ or mg/m³. Manganese, hexavalent chromium, nickel and cadmium in welding plumes each carry distinct regulatory limits that require laboratory confirmation.
What we analyze
Personal breathing-zone monitoring via NIOSH 7300 Modified / 7303 multi-metal ICP-AES; enhanced-sensitivity 7303 for trace metals (beryllium, cadmium, arsenic) at low µg/m³; 30+ metals per filter — iron, manganese, nickel, chromium and more; LEV before/after validation; task-based short-duration sampling; and combined fume + total-dust gravimetric from one filter.
Cr(VI) runs in parallel
ICP acid digestion destroys Cr(VI) speciation, so stainless and chrome-alloy work needs a separate Na₂CO₃-treated PVC filter analyzed by OSHA ID-215. We run the metals scan and the Cr(VI) filter in parallel from the same sampling event.
Welding fumes are highly toxic aerosols — and the ACGIH manganese limit is 250× stricter than OSHA's PEL
OSHA PEL Enforcement
Individual metal PELs under 29 CFR 1910.1000 are actively enforced. Citations for manganese, hexavalent chromium and cadmium exposures carry heavy penalties without welding fume testing documentation.
Neurological & Carcinogenic Risk
Manganese causes irreversible Parkinsonism (manganism). Nickel and hexavalent chromium are Group 1 IARC carcinogens. These are dose-dependent, cumulative diseases requiring dedicated IH monitoring.
The Manganese Gap
The ACGIH TLV for manganese (0.02 mg/m³ inhalable) is 250× more stringent than the OSHA PEL ceiling (5 mg/m³). Workers can be fully OSHA-compliant yet at serious neurological risk.
Engineering Control Validation
LEV, fume-extraction guns and welding enclosures reduce exposure — but only accredited welding fume testing proves they achieve levels below the applicable PELs.
Welding process × fume hazard matrix
The metals you need to test for depend entirely on what is being welded and how. Use this to select the right analyte panel before sampling begins.
SMAW — Shielded Metal Arc (Stick)
Highest fume generation rate of any fusion process. Flux coating adds fluorides, potassium and sodium compounds over base and filler-metal oxides. Confined-space stick welding can reach 10–100× open-air fume levels within minutes.
FCAW — Flux-Cored Arc
Similar quantity to SMAW with added flux-core contributions; self-shielded FCAW-S produces more fume than gas-shielded FCAW-G. High-manganese E71T electrodes make Mn monitoring critical; stainless FCAW generates significant Cr(VI).
GMAW — Gas Metal Arc (MIG)
Lower fume per unit weld than SMAW, but high deposition and continuous operation make cumulative exposure comparable. Globular transfer generates more fume than spray. Mild-steel MIG fume is mainly iron and manganese; accumulates fast without LEV.
GTAW — Gas Tungsten Arc (TIG)
Lowest fume on clean base metal, but tungsten tip erosion adds tungsten compounds. TIG on stainless generates hexavalent chromium even at low total fume — the 0.005 mg/m³ Cr(VI) PEL can be exceeded despite TIG's low output.
Plasma Cutting & Arc Gouging
Plasma cutting generates ultrafine particles (<100 nm) that penetrate deeper than larger particles. Arc gouging of stainless or hard-facing alloys produces the full metal-fume spectrum; carbon-arc gouging adds graphite smoke.
Brazing, Soldering & Hot Work
Brazing fillers often contain cadmium (older silver alloys) and zinc. Lead fume arises from soldering, hot work on leaded paint or leaded brass. Zinc oxide from galvanized steel causes metal fume fever; coated metal adds decomposition products.
Health effects of welding fume exposure
Many effects are irreversible by the time symptoms appear — clinical signs and lung-function decline lag years behind tissue damage. Early quantitative IH testing is the only defence.
Manganism Manganese
Irreversible neurological disease from Mn accumulation in the basal ganglia. Resembles Parkinson's — tremor, rigidity, bradykinesia, psychiatric symptoms — but does not respond to levodopa. ACGIH TLV 0.02 mg/m³.
Occupational Lung Cancer IARC Group 1
IARC's 2017 reclassification makes welding fume a definite human carcinogen for lung cancer across all processes, not just stainless. Latency of 15–30 years makes early testing records critical for future legal defence.
Cr(VI) Lung Cancer Hexavalent chromium
Cr(VI) from stainless and chrome-alloy welding is OSHA-regulated (29 CFR 1910.1026). Causes lung, nasal and sinus cancer and septum perforation with chronic high exposure. PEL 0.005 mg/m³ — one of the lowest metal PELs; requires separate sampling.
Metal Fume Fever (MFF) Zinc oxide
Acute flu-like illness 4–8 hours after inhaling freshly generated zinc oxide from galvanized steel, brass or zinc alloys — fever, chills, aches, nausea, chest tightness. Resolves in 24–48 hours but recurs with each exposure.
Siderosis & Pulmonary Fibrosis Iron oxide
Siderosis (iron-oxide deposition) was long considered benign, but recent evidence links heavy deposition to progressive pulmonary fibrosis — especially combined with silica or manganese.
Cadmium Nephropathy Cadmium
Cadmium from brazing alloys, galvanized coatings and plated fasteners is OSHA-regulated. Causes irreversible tubular kidney damage (Fanconi syndrome) and lung cancer. PEL 0.005 mg/m³ warrants immediate testing.
Metal PELs — OSHA vs ACGIH
Every metal is reported against both the OSHA PEL (legal compliance) and the ACGIH TLV (health-based best practice). For manganese, nickel and Cr(VI), the gap between the two is the most important number in your report.
| Metal / compound | OSHA PEL | ACGIH TLV-TWA | Health basis | Standard |
|---|---|---|---|---|
| Manganese (Mn) — inhalable | Ceiling 5 mg/m³ | 0.02 mg/m³ | Manganism (irreversible) | OSHA Z-1 / ACGIH |
| Iron oxide (fume) | 10 mg/m³ | 5 mg/m³ | Siderosis, fibrosis risk | OSHA Z-1 |
| Nickel (insoluble) — IARC Gr.1 | 1 mg/m³ | 0.2 mg/m³ | Lung/nasal cancer, sensitization | OSHA Z-1 |
| Hexavalent chromium — IARC Gr.1 | 0.005 mg/m³ | 0.01 mg/m³ | Lung cancer, septum perforation | 1910.1026 (ID-215) |
| Cadmium — IARC Gr.1 | 0.005 mg/m³ | 0.01 mg/m³ | Lung cancer, nephropathy | 1910.1027 |
| Lead (Pb) | 0.05 mg/m³ | 0.05 mg/m³ | Neuro, renal, reproductive | 1910.1025 |
| Zinc oxide (fume) | 5 mg/m³ | 2 mg/m³ | Metal fume fever (acute) | OSHA Z-1 |
| Copper (fume) | 0.1 mg/m³ | 0.2 mg/m³ | Respiratory irritation, MFF | OSHA Z-1 |
| Beryllium (Be) — IARC Gr.1 | 0.0002 mg/m³ | 0.00005 mg/m³ | Chronic beryllium disease, cancer | 1910.1024 |
OSHA PELs as 8-hour TWA unless noted as ceiling. Cr(VI) requires separate OSHA ID-215 sampling on a Na₂CO₃-treated PVC filter.
Laboratory methods for welding fume analysis
Targeted welding fume testing uses the same ICP platform as our full metals scan, but the analyte panel and collection strategy are tailored to the welding process and regulatory requirements.
NIOSH 7300 Modified — Targeted Fume Panel
Configured for the metals relevant to the process: Mn, Fe, Ni, Cr (total), Cu, Zn, Pb, Cd and others. Each reported against OSHA PEL and ACGIH TLV, with manganese flagged explicitly against the ACGIH limit.
OSHA ID-215 — Hexavalent Chromium
Cr(VI) needs a dedicated method entirely separate from ICP total metals. Air is collected on a 37mm PVC filter treated with Na₂CO₃, which stabilizes Cr(VI) against reduction. Mandatory for stainless — Cr(VI) requires ID-215 speciation.
Total Fume Gravimetric + ICP
Determines total welding fume mass in mg/m³ (gravimetric, NIOSH 0500/0600) and individual metal concentrations in µg/m³ (ICP, NIOSH 7300 Mod) from the same MCE filter — total fume load for comparison with NIOSH's 1 mg/m³ recommendation for unclassified fume.
Stainless steel welding? Cr(VI) requires a separate dedicated test
NIOSH 7300 Modified / 7303 acid digestion destroys Cr(VI) speciation — the hexavalent form is measured by the dedicated OSHA ID-215 method. OSHA 1910.1026 requires Cr(VI)-specific sampling (OSHA ID-215, Na₂CO₃-treated PVC filter) for any stainless or chrome-alloy welding. AGT Labs analyzes both in parallel — see our hexavalent chromium testing page.
Welding fume sampling field requirements
Contamination and filter-handling errors are the primary sources of invalid data — metal contamination from field handling can falsely elevate results.
Cassette placement & media
Representativeness & tasks
COC documentation — critical fields
Manganese — special considerations
Turnaround times & sampling kits
OSHA's Cr(VI) (1910.1026), cadmium (1910.1027), lead (1910.1025) and beryllium (1910.1024) standards require periodic re-monitoring whenever a process, consumable or control changes. Set up a recurring program for held media and volume pricing.
Sampling media & equipment
- 37mm MCE filters (0.8 µm) — acid-cleaned, blank-tested
- Na₂CO₃-coated PVC cassettes for Cr(VI) (OSHA ID-215)
- Acid-cleaned closed-face cassette holders
- Calibrated personal air sampling pumps — loaner program
- Field blanks (pre-labeled, per batch)
- IH chain of custody + pre-paid UPS return shipping
Who relies on AGT Labs for welding fume testing
Metal Fabrication & Shipbuilding
Structural-steel fabricators, pipe shops and shipyards — routine testing for Mn, Fe, Ni and Cr(VI) for OSHA compliance and ACGIH TLV documentation, SMAW and FCAW operations included.
Oil & Gas / Petrochemical
Pipeline welding, vessel fabrication and turnaround maintenance — stainless and alloy welding generates Cr(VI), nickel and manganese. Critical for 1910.1026 Cr(VI) compliance.
Structural Steel & Bridge
Hot work on pre-1978 steel, bridge maintenance and industrial painting — fume testing for lead-painted substrate exposure alongside iron oxide and manganese ICP before respiratory-program design.
Aerospace & Defense
TIG on titanium and beryllium-copper alloys — NIOSH 7303 enhanced-sensitivity ICP for beryllium at the 0.1 µg/m³ action level for 1910.1024 compliance documentation.
IH Consultants & EH&S
Consulting firms and EHS departments — accredited ICP results formatted for client reports, OSHA response packages and engineering-control ROI documentation.
Federal & DoD Facilities
Shipyard maintenance, ammunition plants and federal cleanup — our AIHA LAP (LAP-101470) and ISO/IEC 17025 system meets federal data-quality requirements for metal-fume monitoring.
Welding fume testing at our accredited IH lab
All ICP-AES and Cr(VI) analysis is performed in-house at our AIHA LAP-accredited lab in the Houston Ship Channel corridor — no send-outs, no third-party delays.
Fabrication & Shipbuilding
Manganese and iron-oxide monitoring for Houston structural-steel fabricators, pipe shops and shipyards — SMAW and FCAW with OSHA PEL and ACGIH TLV on every result, including the 250× manganese gap.
Petrochemical & Refinery
Stainless and alloy welding for Ship Channel refineries, petrochemical plants and LNG facilities — NIOSH 7300 Mod metals scan plus OSHA ID-215 Cr(VI) for 1910.1026 on pressure-vessel and pipe work.
Structural Steel & Bridge
Hot work on pre-1978 steel, bridge maintenance and industrial painting — fume testing for lead-painted substrate exposure alongside iron oxide and manganese ICP.
Aerospace & Defense
TIG on titanium and beryllium-copper for Houston aerospace and defense contractors — NIOSH 7303 enhanced-sensitivity ICP for beryllium at the 0.1 µg/m³ action level.
Welding fume testing — frequently asked questions
What metals are found in welding fume?
What is the OSHA PEL for welding fumes?
What is the difference between NIOSH 7300 Modified and 7303?
Why is manganese the most critical metal in welding fume testing?
Can you test for hexavalent chromium during welding fume testing?
What is metal fume fever and which metals cause it?
Which welding processes generate the most hazardous fumes?
How should I sample for welding fume correctly?
Do you supply sampling pumps for welding fume testing?
Is AGT Labs accredited for welding fume testing?
Frequently paired with welding fume testing
Facilities with active welding programs typically also require companion testing for metal speciation, full ICP scans or lead compliance from the same sampling event.
Metals in Air Testing — Full ICP Scan
When multiple metal sources are present beyond welding — blasting, grinding, foundry, smelting — the full 30+ element NIOSH 7300 Modified scan gives the complete airborne-metal profile.
View metals testing →Hexavalent Chromium Cr(VI) Testing
OSHA ID-215 ion chromatography — the only method that distinguishes Cr(VI) from total chromium. Mandatory for stainless and chrome-alloy welding under 1910.1026.
View Cr(VI) testing →Lead Testing — 29 CFR 1910.1025
Dedicated lead compliance monitoring — NIOSH 7303 enhanced-sensitivity ICP at the 30 µg/m³ action level. Ordered alongside fume testing for hot work on lead-painted steel or leaded brass.
View lead testing →Total & Respirable Dust Testing
Gravimetric dust from the same MCE filter — total fume load in mg/m³ against the NIOSH 1 mg/m³ recommendation, alongside per-metal ICP.
View dust testing →BTEX & VOC Testing
For enclosed fabrication and shipyards where anti-spatter coatings, solvents or primer fumes are present alongside welding aerosols.
View VOC testing →Isocyanate Testing
For shops where coating, bonding or foam work accompanies welding — isocyanate vapor and aerosol monitoring under the applicable OELs.
View isocyanate testing →Ready to submit welding fume samples to an accredited IH lab?
AIHA LAP (LAP-101470) · ISO/IEC 17025:2017 · NIOSH 7300 Modified & OSHA ID-215 · 30+ metals per filter · OSHA PEL + ACGIH TLV on every result · rush 1-day TAT · Houston TX. Ask about recurring monitoring programs and volume pricing.