Login Media Request Request Quote COC / Sample Submission Form

AGT Labs Industrial Hygiene

Welding Fume Testing Laboratory in Houston, TX

AGT Labs analyzes samples collected by your industrial hygienist, EHS team or consultant — drop off in Houston or ship from anywhere in the U.S. ICP-AES analysis for manganese, iron oxide, nickel, hexavalent chromium, cadmium, lead, zinc oxide and 30+ metals from a single filter, with NIOSH 7300 Modified / 7303 compliance reporting for personal breathing-zone assessments and LEV validation. AIHA LAP accredited (LAP-101470) and ISO/IEC 17025:2017 — results reported against both the OSHA PEL and the ACGIH TLV, accepted nationwide.

For inspectors & consultants

We're the accredited lab behind your sample results

A welding fume or industrial hygiene inspector or consultant? Submit your MCE and Cr(VI) cassettes to our AIHA LAP-accredited ICP lab under your own independent-lab account — per-metal µg/m³ concentrations with OSHA PEL and ACGIH TLV comparisons formatted for your reports.

Independent Lab Testing →
IH testing laboratory

What is welding fume testing?

Welding fume testing collects airborne metal particulate from a welder's breathing zone on a calibrated pump and MCE filter, then analyzes that filter by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES). The instrument atomizes and ionizes the acid-digested filter in a ~8,000°C plasma and quantifies each element by its emission spectrum — simultaneous quantification of 30+ metals from one filter, each reported in µg/m³ or mg/m³. Manganese, hexavalent chromium, nickel and cadmium in welding plumes each carry distinct regulatory limits that require laboratory confirmation.

What we analyze

Personal breathing-zone monitoring via NIOSH 7300 Modified / 7303 multi-metal ICP-AES; enhanced-sensitivity 7303 for trace metals (beryllium, cadmium, arsenic) at low µg/m³; 30+ metals per filter — iron, manganese, nickel, chromium and more; LEV before/after validation; task-based short-duration sampling; and combined fume + total-dust gravimetric from one filter.

Cr(VI) runs in parallel

ICP acid digestion destroys Cr(VI) speciation, so stainless and chrome-alloy work needs a separate Na₂CO₃-treated PVC filter analyzed by OSHA ID-215. We run the metals scan and the Cr(VI) filter in parallel from the same sampling event.

Why welding fume testing matters

Welding fumes are highly toxic aerosols — and the ACGIH manganese limit is 250× stricter than OSHA's PEL

OSHA PEL Enforcement

Individual metal PELs under 29 CFR 1910.1000 are actively enforced. Citations for manganese, hexavalent chromium and cadmium exposures carry heavy penalties without welding fume testing documentation.

Neurological & Carcinogenic Risk

Manganese causes irreversible Parkinsonism (manganism). Nickel and hexavalent chromium are Group 1 IARC carcinogens. These are dose-dependent, cumulative diseases requiring dedicated IH monitoring.

The Manganese Gap

The ACGIH TLV for manganese (0.02 mg/m³ inhalable) is 250× more stringent than the OSHA PEL ceiling (5 mg/m³). Workers can be fully OSHA-compliant yet at serious neurological risk.

Engineering Control Validation

LEV, fume-extraction guns and welding enclosures reduce exposure — but only accredited welding fume testing proves they achieve levels below the applicable PELs.

Process-specific fume risk

Welding process × fume hazard matrix

The metals you need to test for depend entirely on what is being welded and how. Use this to select the right analyte panel before sampling begins.

Highest fume

SMAW — Shielded Metal Arc (Stick)

Highest fume generation rate of any fusion process. Flux coating adds fluorides, potassium and sodium compounds over base and filler-metal oxides. Confined-space stick welding can reach 10–100× open-air fume levels within minutes.

Watch: iron oxide, manganese, fluorides, potassium; nickel & Cr(VI) on stainless
High · flux

FCAW — Flux-Cored Arc

Similar quantity to SMAW with added flux-core contributions; self-shielded FCAW-S produces more fume than gas-shielded FCAW-G. High-manganese E71T electrodes make Mn monitoring critical; stainless FCAW generates significant Cr(VI).

Watch: manganese, iron oxide, fluorides; Cr(VI) & nickel on stainless
Moderate-high

GMAW — Gas Metal Arc (MIG)

Lower fume per unit weld than SMAW, but high deposition and continuous operation make cumulative exposure comparable. Globular transfer generates more fume than spray. Mild-steel MIG fume is mainly iron and manganese; accumulates fast without LEV.

Watch: iron oxide, manganese, copper, silicon; Cr(VI) on stainless
Stainless · Cr(VI)

GTAW — Gas Tungsten Arc (TIG)

Lowest fume on clean base metal, but tungsten tip erosion adds tungsten compounds. TIG on stainless generates hexavalent chromium even at low total fume — the 0.005 mg/m³ Cr(VI) PEL can be exceeded despite TIG's low output.

Watch: tungsten, Cr(VI) & nickel on stainless, ozone
Ultrafine

Plasma Cutting & Arc Gouging

Plasma cutting generates ultrafine particles (<100 nm) that penetrate deeper than larger particles. Arc gouging of stainless or hard-facing alloys produces the full metal-fume spectrum; carbon-arc gouging adds graphite smoke.

Watch: iron, manganese, Cr(VI) on stainless, zinc (galv.), ultrafines
Coatings

Brazing, Soldering & Hot Work

Brazing fillers often contain cadmium (older silver alloys) and zinc. Lead fume arises from soldering, hot work on leaded paint or leaded brass. Zinc oxide from galvanized steel causes metal fume fever; coated metal adds decomposition products.

Watch: cadmium, lead, zinc oxide, silver, copper
Occupational health impacts

Health effects of welding fume exposure

Many effects are irreversible by the time symptoms appear — clinical signs and lung-function decline lag years behind tissue damage. Early quantitative IH testing is the only defence.

Manganism Manganese

Irreversible neurological disease from Mn accumulation in the basal ganglia. Resembles Parkinson's — tremor, rigidity, bradykinesia, psychiatric symptoms — but does not respond to levodopa. ACGIH TLV 0.02 mg/m³.

Occupational Lung Cancer IARC Group 1

IARC's 2017 reclassification makes welding fume a definite human carcinogen for lung cancer across all processes, not just stainless. Latency of 15–30 years makes early testing records critical for future legal defence.

Cr(VI) Lung Cancer Hexavalent chromium

Cr(VI) from stainless and chrome-alloy welding is OSHA-regulated (29 CFR 1910.1026). Causes lung, nasal and sinus cancer and septum perforation with chronic high exposure. PEL 0.005 mg/m³ — one of the lowest metal PELs; requires separate sampling.

Metal Fume Fever (MFF) Zinc oxide

Acute flu-like illness 4–8 hours after inhaling freshly generated zinc oxide from galvanized steel, brass or zinc alloys — fever, chills, aches, nausea, chest tightness. Resolves in 24–48 hours but recurs with each exposure.

Siderosis & Pulmonary Fibrosis Iron oxide

Siderosis (iron-oxide deposition) was long considered benign, but recent evidence links heavy deposition to progressive pulmonary fibrosis — especially combined with silica or manganese.

Cadmium Nephropathy Cadmium

Cadmium from brazing alloys, galvanized coatings and plated fasteners is OSHA-regulated. Causes irreversible tubular kidney damage (Fanconi syndrome) and lung cancer. PEL 0.005 mg/m³ warrants immediate testing.

Regulatory limits

Metal PELs — OSHA vs ACGIH

Every metal is reported against both the OSHA PEL (legal compliance) and the ACGIH TLV (health-based best practice). For manganese, nickel and Cr(VI), the gap between the two is the most important number in your report.

Metal / compoundOSHA PELACGIH TLV-TWAHealth basisStandard
Manganese (Mn) — inhalableCeiling 5 mg/m³0.02 mg/m³Manganism (irreversible)OSHA Z-1 / ACGIH
Iron oxide (fume)10 mg/m³5 mg/m³Siderosis, fibrosis riskOSHA Z-1
Nickel (insoluble) — IARC Gr.11 mg/m³0.2 mg/m³Lung/nasal cancer, sensitizationOSHA Z-1
Hexavalent chromium — IARC Gr.10.005 mg/m³0.01 mg/m³Lung cancer, septum perforation1910.1026 (ID-215)
Cadmium — IARC Gr.10.005 mg/m³0.01 mg/m³Lung cancer, nephropathy1910.1027
Lead (Pb)0.05 mg/m³0.05 mg/m³Neuro, renal, reproductive1910.1025
Zinc oxide (fume)5 mg/m³2 mg/m³Metal fume fever (acute)OSHA Z-1
Copper (fume)0.1 mg/m³0.2 mg/m³Respiratory irritation, MFFOSHA Z-1
Beryllium (Be) — IARC Gr.10.0002 mg/m³0.00005 mg/m³Chronic beryllium disease, cancer1910.1024

OSHA PELs as 8-hour TWA unless noted as ceiling. Cr(VI) requires separate OSHA ID-215 sampling on a Na₂CO₃-treated PVC filter.

Analytical methods

Laboratory methods for welding fume analysis

Targeted welding fume testing uses the same ICP platform as our full metals scan, but the analyte panel and collection strategy are tailored to the welding process and regulatory requirements.

01

NIOSH 7300 Modified — Targeted Fume Panel

Configured for the metals relevant to the process: Mn, Fe, Ni, Cr (total), Cu, Zn, Pb, Cd and others. Each reported against OSHA PEL and ACGIH TLV, with manganese flagged explicitly against the ACGIH limit.

Standard: NIOSH 7300 Mod / OSHA 125G Mod
Media: 37mm MCE, 0.8 µm, closed-face
Flow: 1.7–3.0 L/min
02

OSHA ID-215 — Hexavalent Chromium

Cr(VI) needs a dedicated method entirely separate from ICP total metals. Air is collected on a 37mm PVC filter treated with Na₂CO₃, which stabilizes Cr(VI) against reduction. Mandatory for stainless — Cr(VI) requires ID-215 speciation.

Standard: OSHA ID-215
Media: 37mm PVC + Na₂CO₃
Note: separate filter from 7300
03

Total Fume Gravimetric + ICP

Determines total welding fume mass in mg/m³ (gravimetric, NIOSH 0500/0600) and individual metal concentrations in µg/m³ (ICP, NIOSH 7300 Mod) from the same MCE filter — total fume load for comparison with NIOSH's 1 mg/m³ recommendation for unclassified fume.

Standards: NIOSH 0500 + 7300 Mod
Media: pre-weighed 37mm MCE
Report: mg/m³ total + µg/m³ per metal

Stainless steel welding? Cr(VI) requires a separate dedicated test

NIOSH 7300 Modified / 7303 acid digestion destroys Cr(VI) speciation — the hexavalent form is measured by the dedicated OSHA ID-215 method. OSHA 1910.1026 requires Cr(VI)-specific sampling (OSHA ID-215, Na₂CO₃-treated PVC filter) for any stainless or chrome-alloy welding. AGT Labs analyzes both in parallel — see our hexavalent chromium testing page.

Field protocol reference

Welding fume sampling field requirements

Contamination and filter-handling errors are the primary sources of invalid data — metal contamination from field handling can falsely elevate results.

Cassette placement & media

Position: collar or hard-hat brim within 30 cm of nose/mouth — inside any respiratory hood if worn
With respirator: sample outside the helmet (ambient) and inside the breathing zone
Cr(VI) media: separate Na₂CO₃-coated PVC filter (in our Cr(VI) kit); ICP metals use a separate MCE filter
Flow: 1.7–3.0 L/min for fume metals (MCE); 1.0–4.0 L/min for Cr(VI) — record each cassette separately

Representativeness & tasks

Shift coverage: cover a representative portion of the full shift, not just the welding period — TWA needs total shift time
Multiple welders: sample each distinct job/task separately; MIG-on-mild-steel differs from TIG-on-stainless
LEV: document whether local exhaust, fume-extraction gun or dilution ventilation ran during sampling

COC documentation — critical fields

Required: worker ID, job title, exact task, base metal, consumable/electrode, process (MIG/TIG/SMAW/FCAW)
Analyte selection: specify "NIOSH 7300 Mod full metals scan" or list target metals; for stainless, add "+ OSHA ID-215 Cr(VI)"
Shipping: original holders, upright; ship Na₂CO₃ Cr(VI) filters promptly — Cr(VI) reduces to Cr(III) over time

Manganese — special considerations

Why critical: OSHA ceiling 5 mg/m³ vs ACGIH TLV 0.02 mg/m³ — a welder can be below the ceiling yet at 250× the TLV
LOD requirement: sample volume must be large enough to collect detectable Mn mass above the method LOD near the TLV
Inhalable vs respirable: the 0.02 mg/m³ TLV is inhalable — open-face at 2.0 L/min is appropriate for TLV comparison
Lab logistics

Turnaround times & sampling kits

OSHA's Cr(VI) (1910.1026), cadmium (1910.1027), lead (1910.1025) and beryllium (1910.1024) standards require periodic re-monitoring whenever a process, consumable or control changes. Set up a recurring program for held media and volume pricing.

Turnaround — welding fume testing
1-Day Rush1 business day+100%
2-Day Rush2 business days+75%
3-Day Rush3 business days+50%
4-Day Rush4 business days+25%
Standard5+ business daysNo Surcharge
Samples received before 2:00 PM CT are logged the same day. For combined fume + Cr(VI) orders, the Cr(VI) schedule applies. Call (713) 453-6090 to confirm rush capacity.

Sampling media & equipment

  • 37mm MCE filters (0.8 µm) — acid-cleaned, blank-tested
  • Na₂CO₃-coated PVC cassettes for Cr(VI) (OSHA ID-215)
  • Acid-cleaned closed-face cassette holders
  • Calibrated personal air sampling pumps — loaner program
  • Field blanks (pre-labeled, per batch)
  • IH chain of custody + pre-paid UPS return shipping
Download IH COC Form →
Industries & clients

Who relies on AGT Labs for welding fume testing

Metal Fabrication & Shipbuilding

Structural-steel fabricators, pipe shops and shipyards — routine testing for Mn, Fe, Ni and Cr(VI) for OSHA compliance and ACGIH TLV documentation, SMAW and FCAW operations included.

Oil & Gas / Petrochemical

Pipeline welding, vessel fabrication and turnaround maintenance — stainless and alloy welding generates Cr(VI), nickel and manganese. Critical for 1910.1026 Cr(VI) compliance.

Structural Steel & Bridge

Hot work on pre-1978 steel, bridge maintenance and industrial painting — fume testing for lead-painted substrate exposure alongside iron oxide and manganese ICP before respiratory-program design.

Aerospace & Defense

TIG on titanium and beryllium-copper alloys — NIOSH 7303 enhanced-sensitivity ICP for beryllium at the 0.1 µg/m³ action level for 1910.1024 compliance documentation.

IH Consultants & EH&S

Consulting firms and EHS departments — accredited ICP results formatted for client reports, OSHA response packages and engineering-control ROI documentation.

Federal & DoD Facilities

Shipyard maintenance, ammunition plants and federal cleanup — our AIHA LAP (LAP-101470) and ISO/IEC 17025 system meets federal data-quality requirements for metal-fume monitoring.

Houston TX IH laboratory

Welding fume testing at our accredited IH lab

All ICP-AES and Cr(VI) analysis is performed in-house at our AIHA LAP-accredited lab in the Houston Ship Channel corridor — no send-outs, no third-party delays.

Primary sector

Fabrication & Shipbuilding

Manganese and iron-oxide monitoring for Houston structural-steel fabricators, pipe shops and shipyards — SMAW and FCAW with OSHA PEL and ACGIH TLV on every result, including the 250× manganese gap.

Oil & gas

Petrochemical & Refinery

Stainless and alloy welding for Ship Channel refineries, petrochemical plants and LNG facilities — NIOSH 7300 Mod metals scan plus OSHA ID-215 Cr(VI) for 1910.1026 on pressure-vessel and pipe work.

Maintenance

Structural Steel & Bridge

Hot work on pre-1978 steel, bridge maintenance and industrial painting — fume testing for lead-painted substrate exposure alongside iron oxide and manganese ICP.

Advanced mfg

Aerospace & Defense

TIG on titanium and beryllium-copper for Houston aerospace and defense contractors — NIOSH 7303 enhanced-sensitivity ICP for beryllium at the 0.1 µg/m³ action level.

Client support

Welding fume testing — frequently asked questions

What metals are found in welding fume?
Depending on process and base metal: manganese, iron oxide, nickel, hexavalent chromium, cadmium, lead, zinc oxide, copper, beryllium and others. Our NIOSH 7300 Modified ICP scan quantifies 30+ metals from a single MCE filter, each reported against its OSHA PEL and ACGIH TLV.
What is the OSHA PEL for welding fumes?
There is no single "welding fume" PEL — OSHA regulates each metal separately under 29 CFR 1910.1000 and the substance-specific standards. The most restrictive include Cr(VI) and cadmium at 0.005 mg/m³ and the manganese ceiling at 5 mg/m³. We report each metal against its own limit.
What is the difference between NIOSH 7300 Modified and 7303?
Both are ICP-AES multi-metal methods. 7303 uses a hot-block acid digestion that gives enhanced sensitivity for trace metals (beryllium, cadmium, arsenic) at low µg/m³, so it's preferred when action-level confirmation on those metals matters. 7300 Modified covers the standard fume panel.
Why is manganese the most critical metal in welding fume testing?
The ACGIH TLV (0.02 mg/m³ inhalable) is 250× stricter than the OSHA ceiling (5 mg/m³). A welder can be fully OSHA-compliant yet exposed well above the health-based limit, so we flag manganese against the ACGIH TLV explicitly in every report.
Can you test for hexavalent chromium during welding fume testing?
Yes, but Cr(VI) needs a separate Na₂CO₃-treated PVC filter analyzed by OSHA ID-215 — ICP acid digestion destroys Cr(VI) speciation. For stainless or chrome-alloy welding we run the ID-215 Cr(VI) filter in parallel with the 7300 metals scan from the same sampling event.
What is metal fume fever and which metals cause it?
An acute flu-like illness 4–8 hours after inhaling freshly generated zinc oxide (from galvanized steel, brass or zinc alloys) and sometimes copper fume. Symptoms — fever, chills, aches, chest tightness — resolve in 24–48 hours but recur with each exposure.
Which welding processes generate the most hazardous fumes?
SMAW (stick) and FCAW produce the highest fume rates; confined-space stick welding can reach 10–100× open-air levels. TIG on stainless is low-fume but still generates Cr(VI). Match the analyte panel to the process and base metal.
How should I sample for welding fume correctly?
Clip an MCE cassette within 30 cm of the breathing zone (inside the hood if worn), run 1.7–3.0 L/min across a representative shift portion, keep cassettes upright, and document process, base metal, consumable and task on the COC. Add a separate Na₂CO₃ PVC filter for Cr(VI) on stainless.
Do you supply sampling pumps for welding fume testing?
Yes — acid-cleaned MCE filters and holders, Na₂CO₃-coated Cr(VI) cassettes, calibrated personal pumps through our loaner program, field blanks and a pre-paid return label.
Is AGT Labs accredited for welding fume testing?
Yes — AIHA LAP (LAP-101470) and ISO/IEC 17025:2017. All ICP-AES and Cr(VI) analysis is performed in-house in Houston, with no send-outs. Samples received before 2:00 PM CT are logged the same day.
Get started

Ready to submit welding fume samples to an accredited IH lab?

AIHA LAP (LAP-101470) · ISO/IEC 17025:2017 · NIOSH 7300 Modified & OSHA ID-215 · 30+ metals per filter · OSHA PEL + ACGIH TLV on every result · rush 1-day TAT · Houston TX. Ask about recurring monitoring programs and volume pricing.